Data Sheet of a Typical SCALEXIO Rack with HighFlex and MultiCompact Hardware

Technical data

The following table shows the general technical data of a typical 9 U and 12 U SCALEXIO rack. (For technical data of the processing hardware, the I/O boards, and the I/O units installed, refer to the data sheets of the related components.)

Parameter

Specification

Environment

Indoor use

Altitude

Up to 2000 m AMSL

Operating temperature

0 °C ... +40 °C (+32 … +104 °F)

Storage temperature

-20 °C … +80 °C (-4 °F … +176 °F)

Relative humidity

80% max. if < +31 °C (+87.8 °F), decreases linearly to 50% at +40 °C (+104 °F), noncondensing

Pollution degree

2, according to IEC 664 (normal clean and dry environment)

Protection class

1

Overvoltage category

II (according to EN 61010-1)

Power source connection

Nominal1)

100 V … 240 V AC, 50 … 60 Hz, 15 A (per power source connector)

Ground swing2)

10 V (max.)

Measurement category

I. (all the I/O signals are intended to be within the safety extra-low voltage (SELV) limits)

Rated current, rated voltage

Board-specific, refer to the related data sheets.

Battery simulation controller

The SCALEXIO system can be equipped with one of the following battery simulation controllers:

Battery simulation power supply unit

The SCALEXIO system can be equipped with one of the following battery simulation power supply units:

  • A battery simulation power supply unit of the GenesysTM 1500W series:

    • GEN20-76 (20 V, 76 A)3)

    • GEN40-38 (40 V, 38 A)

    • GEN60-25 (60 V, 25 A)

  • A battery simulation power supply unit of the Delta Elektronika SM 1500 series4):

    • SM 15-100 (15 V, 100 A)

    • SM 35-45 (35 V, 45 A)

  • A customer-specific battery simulation power supply unit.4)

Output power of the rack-internal +24 V power supply units

  • 9 HU SCALEXIO system: 1x 300 W (max.)

  • 12 HU SCALEXIO system: 2x 300 W (max.)

+24 V external power supply output

10 A (max.), 240 W (max.)5)

Power consumption of rack-internal fan units

3x 7.2 W (max.)

Physical size of enclosure

19" rack system, 9 HU or 12 HU

9 HU: 560 × 540 × 540 mm (width × height × depth)

12 HU: 560 × 675 × 540 mm (width × height × depth)

Mass

Depends on the individual system setup

  1. According to EN 61010‑1, fluctuations in the power supply voltage of up to ±10% of the nominal voltage are permissible.

  2. Output swing between signal ground (KL 31) and earth ground (PE), refer to Ground Potentials.

  3. The GEN20-76 is the default battery simulation power supply unit.

  4. Contact dSPACE if you want to use a Delta Elektronika or a customer-specific power supply unit.

  5. The power that is externally consumed reduces the power to operate the rack-internal I/O units and boards.


CE compliance

A typical SCALEXIO rack meets the requirements of the EU directives 2014/30/EU (Electromagnetic Compatibility Directive) and 2014/35/EU (Low Voltage Directive) for CE marking. For more information, refer to Certifications and CE Compliance of SCALEXIO Hardware.