The following table shows the general technical data of a typical 9 U and 12 U SCALEXIO rack. (For technical data of the processing hardware, the I/O boards, and the I/O units installed, refer to the data sheets of the related components.)
Parameter | Specification | |
|---|---|---|
Environment | Indoor use | |
Altitude | Up to 2000 m AMSL | |
Operating temperature | 0 °C ... +40 °C (+32 … +104 °F) | |
Storage temperature | -20 °C … +80 °C (-4 °F … +176 °F) | |
Relative humidity | 80% max. if < +31 °C (+87.8 °F), decreases linearly to 50% at +40 °C (+104 °F), noncondensing | |
Pollution degree | 2, according to IEC 664 (normal clean and dry environment) | |
Protection class | 1 | |
Overvoltage category | II (according to EN 61010-1) | |
Power source connection | Nominal1) | 100 V … 240 V AC, 50 … 60 Hz, 15 A (per power source connector) |
Ground swing2) | 10 V (max.) | |
Measurement category | I. (all the I/O signals are intended to be within the safety extra-low voltage (SELV) limits) | |
Rated current, rated voltage | Board-specific, refer to the related data sheets. | |
Battery simulation controller | The SCALEXIO system can be equipped with one of the following battery simulation controllers:
| |
Battery simulation power supply unit | The SCALEXIO system can be equipped with one of the following battery simulation power supply units:
| |
Output power of the rack-internal +24 V power supply units |
| |
+24 V external power supply output | 10 A (max.), 240 W (max.)5) | |
Power consumption of rack-internal fan units | 3x 7.2 W (max.) | |
Physical size of enclosure | 19" rack system, 9 HU or 12 HU 9 HU: 560 × 540 × 540 mm (width × height × depth) 12 HU: 560 × 675 × 540 mm (width × height × depth) | |
Mass | Depends on the individual system setup | |
According to EN 61010‑1, fluctuations in the power supply voltage of up to ±10% of the nominal voltage are permissible.
Output swing between signal ground (KL 31) and earth ground (PE), refer to Ground Potentials.
The GEN20-76 is the default battery simulation power supply unit.
Contact dSPACE if you want to use a Delta Elektronika or a customer-specific power supply unit.
The power that is externally consumed reduces the power to operate the rack-internal I/O units and boards.
A typical SCALEXIO rack meets the requirements of the EU directives 2014/30/EU (Electromagnetic Compatibility Directive) and 2014/35/EU (Low Voltage Directive) for CE marking. For more information, refer to Certifications and CE Compliance of SCALEXIO Hardware.