You can reuse RTI models for MiroLabBox by deleting the RTI blocks in the Simulink model and adding comparable function blocks in ConfigurationDesk.
When the function blocks are added to the signal chain, you can generate the interface to the Simulink model in ConfigurationDesk.
For adding function blocks to the signal chain, refer to Implementing I/O Functionality .
For generating the model interface, refer to Basics on Adding Model Port Blocks to the Signal Chain.
The minimum ConfigurationDesk version to support the MicroLabBox II is ConfigurationDesk 23.2, Release 2023-B.
The following table shows comparable function blocks for replacing RTI blocks supporting A/D conversion.
RTI Block of the Real-Time Interface Blockset | Comparable Function Block Type of ConfigurationDesk | Notes |
|---|---|---|
ADC_CLASS1_BLx |
| Scaling of conversion result required. |
ADC_CLASS1_START_BLx | Obsolete | ‑ |
ADC_CLASS1_FAILURE_BLx | Obsolete | |
ADC_CLASS2_BLx | Voltage In | Scaling of conversion result required. |
The following table shows comparable function blocks for replacing RTI blocks supporting D/A conversion.
RTI Block of the Real-Time Interface Blockset | Comparable Function Block Type of ConfigurationDesk | Notes |
|---|---|---|
DAC_CLASS1_BLx | Voltage Out | Scaling of voltage range required. |
The following table shows comparable function blocks for replacing RTI blocks supporting bit I/O.
RTI Block of the Real-Time Interface Blockset | Comparable Function Block Type of ConfigurationDesk | Notes |
|---|---|---|
DIO_CLASS1_BIT_IN_BLx | Multi Bit In | ‑ |
DIO_CLASS1_BIT_OUT_BLx | Multi Bit Out | ‑ |
The following table shows comparable function blocks for replacing RTI blocks supporting timing I/O.
RTI Block of the Real-Time Interface Blockset | Comparable Function Block Type of ConfigurationDesk | Notes |
|---|---|---|
DIO_CLASS1_PWM_BLx | PWM/PFM Out | Scaling of duty cycle required. |
DIO_CLASS1_PWM2D_BLx | PWM/PFM In | Scaling of duty cycle required. |
DIO_CLASS1_PULSE_BLx | Digital Pulse Out | ‑ |
DIO_CLASS1_PW2D_BLx | Not available | As an alternative, you can use one of the following function block types:
|
The following table shows comparable function blocks for replacing RTI blocks supporting electric motor control.
RTI Block of the Real-Time Interface Blockset | Comparable Function Block Type of ConfigurationDesk | Notes |
|---|---|---|
EMC_BC_PWM_BLx | Block-Commutated PWM Out | ‑ |
EMC_ENCODER_BLx | Digital Incremental Encoder In | ‑ |
EMC_ENDAT_BLx | EnDat Master | ‑ |
EMC_HALL_BLx | Hall Encoder In | ‑ |
EMC_MC_PWM_BLx | Multi-Channel PWM Out | ‑ |
EMC_RESOLVER_BLx | Resolver In | ‑ |
EMC_SSI_BLx | SSI Master | ‑ |
The following table shows comparable function blocks for replacing RTI blocks supporting serial communication.
RTI Block of the Real-Time Interface Blockset | Comparable Function Block Type of ConfigurationDesk | Notes |
|---|---|---|
DS1202SER_STAT_Cx | UART | Line status flags supported only. To read the modem status flags, you must program a custom function block. Refer to Example of Complex UART Serial Communication (RS232 FlowControl) Using a DS2671 Bus Board. |
DS1202SER_TX_Cx | ||
DS1202SER_RX_Cx | ||
DS1202SER_INT_Cx_Iy | ||
DS1202SER_SETUP_Cx | Obsolete | ‑ |
The following table shows comparable function blocks for replacing the RTI CAN blocksets.
Real-Time Interface Blockset | Comparable Function Block Types of ConfigurationDesk | Notes |
|---|---|---|
RTI CAN Blockset | CAN | The CAN function block is one part of implementing CAN communication in real-time applications. The CAN communication itself must be modeled with the Bus Manager in ConfigurationDesk. Refer to Information for Former Users of the RTI CAN MultiMessage Blockset and RTI LIN MultiMessage Blockset. |
RTI CAN MultiMessage Blockset |
The following table shows comparable function blocks for replacing the RTI Ethernet communication.
Real-Time Interface Blockset | Comparable Function Block Type of ConfigurationDesk | Notes |
|---|---|---|
RTI Ethernet (UDP) Blockset | Ethernet Setup | ‑ |
UDP Transmit | ||
UDP Receive |
The following table shows comparable function blocks for replacing RTI blocks supporting SPI communication.
RTI Block of the Real-Time Interface Blockset | Comparable Function Block Type of ConfigurationDesk | Notes |
|---|---|---|
DIO_CLASS1_SPI_RX_BLx | SPI Master | ‑ |
DIO_CLASS1_SPI_TX_BLx | ||
DIO_CLASS1_SPI_CYCLE_SETUP_BLx | ||
DIO_CLASS1_SPI_SETUP_BLx |
The following table shows how the interrupt handling is replaced in ConfigurationDesk.
Blocks of the Real-Time Interface Blockset | Comparable Function Block Type of ConfigurationDesk | Notes |
|---|---|---|
ADC_CLASS1_HWINT_BLx | In ConfigurationDesk, the function blocks can generate I/O events that can be used to trigger asynchronous tasks, for example, the Voltage In function block. For more information, refer to Modeling Asynchronous Tasks. | ‑ |
DIO_CLASS1_HWINT_BLx |
The following table shows comparable function blocks for replacing RTI blocks supporting nonvolatile data handling.
RTI Block of the Real-Time Interface Blockset | Comparable Function Block Type of ConfigurationDesk | Notes |
|---|---|---|
NVDATA_READ_BLx | Non-Volatile Memory Access | ‑ |
NVDATA_WRITE_BLx | ||
USB_FLIGHT_REC_SETUP | Not supported | Replaced by ControlDesk Data Logging. Refer to Introduction to Data Logging. |
USB_FLIGHT_REC_BLx | ||
USB_FLIGHT_REC_EJECT | USB Eject | ‑ |
Instead of the RTI TRC Exclusion block, which excludes all blocks in a subsystem from the generated variable description file (TRC file), you must use subsystem omission tags (DsVdOmit). These tags let you reduce the content of the generated TRC file even more specifically, for example, by excluding variables. Refer to Adapting the Generation of the Variable Description File.