The MicroAutoBox III must be supplied with the correct operating voltage to avoid electric shock and malfunctions.
Make sure that the power supply/vehicle battery does not exceed the maximum operating voltage. The operating voltage range is printed on the type label at the bottom of the MicroAutoBox III.
Do not use plugs for the power supply cable that can lead to an accidental connection to hazardous supply voltages, such as the mains voltage.
Do not use the preconfigured power supply cable from dSPACE at supply voltages > 32 V DC.
For operation with DC voltages > 32 V DC, you must build a power supply cable. For building a power supply cable, refer to Building the Power Supply Cable.
If the Embedded PC is built in a MicroAutoBox III, the power input connector of the Embedded PC is covered with a protective cap. Do not remove the protective cap.
To avoid hardware damage and the risk of electric shock, do not connect the MicroAutoBox III to an AC power source.
A vehicle battery can supply high currents. If a short circuit occurs, e.g., in the cable harness, the current of the vehicle battery (power supply) generates heat in the connected cables. The heat might cause a fire.
Insert fuses into the power supply cable and other cables that are connected to the battery/power supply to avoid an electrical fire.
Locate the fuses close to the battery/power supply.
Choose fuse ratings that ensure that the fuses break the circuit if the connected cables are loaded with the maximum currents supported by the cross sections of the cables used.
Make sure that you use flame-retardant cables specified for temperatures up to 105 °C (220 °F) that were tested in conformity with IEC 60332‑1‑2, IEC 60332‑2‑2, or UL VW‑1.
Make sure that you use flame-retardant connectors specified for temperatures up to 105 °C (220 °F) and V‑2 classified in conformity with IEC 60695‑11‑10 or UL 94.
Even a brief disconnection of the battery during engine operation can cause the vehicle generator to generate hazardous voltages of more than 100 V (load dump).
Turn off the vehicle engine before connecting or disconnecting the vehicle battery.
Batteries cannot be switched off.
Make sure that the power connector can be reached by the user.
Using a power supply cable with non-insulated ends can lead to an electric shock when connecting the MicroAutoBox III to an energized power supply.
The connection of the cable is comparable to switch bouncing. The bouncing, the inrush current, the inductivity of the cable, and the input circuit of the MicroAutoBox III can lead to a hazardous voltage.
Make sure that the power supply cable is removed from the power input connector of the MicroAutoBox III before you connect the non-insulated ends to the battery voltage.
Voltages that are connected to the power input connector of the MicroAutoBox III Cooling Unit are directly looped through to its power output connector.
Make sure that the power output connector of the Cooling Unit is connected to the power input connector of the MicroAutoBox III before you connect the laboratory power supply/vehicle battery.
The screws of the power output connector must always be tight when you power up the Cooling Unit. Do not loosen the screws before the power supply/vehicle battery is disconnected.
The cable of the power output connector must not be kinked or damaged.