You install and uninstall the MicroAutoBox III at your own risk. Any damage to or malfunction of dSPACE hardware caused by improper installation or uninstallation is not covered by the warranty, unless the handling and installation instructions are shown to be defective.
For example, installation work includes:
Mounting a module on a board.
Connecting/disconnecting external devices and the power supply.
Connecting/disconnecting break‑out boxes.
Connecting/disconnecting dSPACE ECU communication and bypass interfaces.
Before doing any installation or uninstallation work, observe the following points:
Check the MicroAutoBox III for external damages. You must not put into operation any damaged hardware.
Disconnect the power supply/vehicle battery.
Disconnect the external devices from the MicroAutoBox III.
In case of a fault, connected external devices might conduct dangerous high voltage to the MicroAutoBox III or parts of the circuitry.
The safety precautions in this document must be carried out for installation work and for system operation.
dSPACE hardware contains sensitive electronic devices. There is a risk of damaging the hardware or reducing its lifetime due to electrical fields or electrostatic discharge (ESD) that occur on touch. To avoid this risk, take the following precautions:
Only qualified persons with knowledge of protective measures for electrostatic sensitive devices are allowed to unpack, install, or remove sensitive electronic devices.
During the transport and storage of a sensitive electronic device, place it in closed ESD packaging.
While handling a sensitive electronic device, place it on a properly grounded workstation, such as a special ESD desk or desk mat.
You must ensure potential equalization between the environment and you, e.g., by wearing a grounded ESD wristband.
Do not touch the board or the contacts of the connectors, even after installing the sensitive electronic device.
To prevent damage to the hardware:
Apply voltages/currents to the connector pins only inside the specified ranges.
Do not connect or disconnect any devices while the MicroAutoBox III is powered up and/or external devices are switched on. Make sure that external devices are turned off beforehand.
Make sure that the wiring material fulfills the required characteristics.
Before you connect an external device to the MicroAutoBox III, use measurement instruments, such as an oscilloscope or a tester device, to verify the I/O signals generated by your MicroAutoBox III. If you cannot test the I/O signals, ensure that no one is in the potential danger zone of the device (test bench, etc.) when the changes first take effect. This can also be necessary if you have updated the firmware or changed the cable harness via a break-out box.
Do not use radio connections for safety-relevant functions. The performance of radio connections can be significantly reduced or the connection can be lost due to radio dead spots, insufficient radio range, radio disturbances, or radio shadow.
The MicroAutoBox III provides electrical energy at the I/O pins, which can cause a fire if external components such as sensors/actuators are not appropriately connected. This particularly concerns the VSENS, VBATprot, and the USB ports pins.
To prevent a fire, apply the general fire safety regulations, e.g., supervise the operation, remove fire loads, and use fire-proof materials and enclosures.
The MicroAutoBox III can provide a DHCP server. If you connect the MicroAutoBox III with activated DHCP server to an Ethernet network that already provides a DHCP server, you disturb or interrupt the communication of other Ethernet devices in the network.
Do not connect the MicroAutoBox III with activated DHCP server to a company network.
Make sure that only one DHCP server is enabled in an Ethernet network.
All the Ethernet ports of the MicroAutoBox III contain safety extra‑low voltage (SELV) circuits, which must be connected only to other SELV circuits.
To avoid electric shock, do not connect the Ethernet ports of the MicroAutoBox III to non‑SELV circuits, e.g., telecommunication network voltage (TNV) circuits.
The LAN or LAN segment of the MicroAutoBox III and all connected equipment must be part of the same low‑voltage power distribution system.
Do not use RJ45 connectors of wide area network (WAN) ports, because WAN ports can contain TNV circuits.
LAN cables can occasionally be subject to hazardous transient voltages, such as lightning or disturbances in the electric utilities power grid. Handle exposed metal components of the network with caution.