If different signal paths have different lengths, the resulting signals are available at different points in time. Synchronous signals become asynchronous due to different signal paths. This might cause unexpected behavior of your application.
For example: The values of three signals are processed to one signal as shown in the following illustration.

If synchronous signals are required for the application, ensure that the signal paths are synchronized. You can do this, for example, by executing an offline simulation to visualize the signals and detect asynchronous paths. Refer to StepĀ 3: How to Simulate the FPGA Functionality in Simulink (Offline Simulation).
To synchronize the length of the signal paths of different signals, you can add delay blocks. With delay blocks, you can extend shorter signal paths to the length of the longest signal path.