Step 5: How to Change the Leading Raster

Objective

If the variables that are connected to the Time Plotter are associated with several measurement rasters, you can select one measurement raster to specify the trigger settings for the Time Plotter display. This raster becomes the leading raster.


Video

Watch the video or follow the written instructions below.


Method: To change the leading raster

  1. Press F6 to stop measuring.

  2. Right-click the 1 ms raster and select Properties.

  3. In the Properties pane, make sure that the following settings are set:

    • Multi-capture history: Enabled

    • Auto repeat: Enabled

    Tip

    Click the pin button to toggle the pane's autohide function.

  4. In the Measurement Configuration pane, select the 1 ms raster and click the 5 ms raster checkbox of the Model Root/Control_out variable in the Platform column of the configuration area.

    The Model Root/Control_out variable is now measured as a 5 ms signal.

    • The Plotter legend displays the new raster setting in the Raster column.

    • The signal trace is not displayed in the analog view area, because no values have been measured in this raster so far.

    • The raster list in the toolbar shows that the 1 ms raster is still used for the Time Plotter display. It is the leading raster.

    • The x-axis of the Plotter is therefore still set to 0.1 seconds.

  5. Press F5 to start measuring.

  6. Change the following settings of Time Plotter B:

    • In the legend, select the Control_out signal.

    • In the toolbar, select the 5 ms raster in the raster list.

    • The 5 ms raster is now the leading raster.

    • The Plotter display is set to continuous mode, because the 5 ms raster is not configured for triggered measurements.

  7. In the Measurement Configuration, right-click Acquisition – Platform and select Measure all Triggered (Enables Triggers and Restarts Rasters).

    All measurement rasters are set to triggered measurement now.

    The Time Plotter B display switches to triggered mode:

  8. In the toolbar of Time Plotter B, click to optimize the trigger settings.

    ControlDesk sets the duration trigger for the 5 ms signal to 0.1 s. The 1 ms signals are visible again without gaps.


Result

You specified to measure a variable in another measurement raster. Then you switched the trigger settings of the Time Plotter display to this raster, which made it the leading raster.


What’s next

In the next step, you can change the default raster for the variables of a device.