When you add a variable description to a dSPACE platform, ControlDesk adds a start trigger and a stop trigger to each measurement raster available for the related application.
Measurement Trigger | Default Setting |
|---|---|
Platform trigger (start trigger) | Disabled |
Duration trigger (stop trigger) | Disabled |
The following illustration shows the Measurement Configuration pane with the default trigger settings of the 1 ms raster of the DAQTutorialExperiment_Meas experiment as an example:

As a result, ControlDesk performs continuous (untriggered) measurements.
You must have prepared the tutorial project.
Refer to How to Prepare the Tutorial Project.
Watch the video or follow the written instructions below.
Open the DAQTutorialProject.
If the DAQTutorialExperiment_Meas experiment is not already active, activate it via its context menu.
Click Variables to open the Variables pane, and select the Model Root node in the group view.
In the variable list, select the following two variables and drag them onto Layout1 to place them in a Time Plotter:
Control_out
Throttle_act_pos

Name the Time Plotter Time Plotter A and open its toolbar (DAQ type) and its legend.

You can open the legend and the toolbar by clicking the arrow symbols in the Time Plotter:

You can select the toolbar type within the toolbar:

On the Home ribbon, click Status Control - Start Measuring to start a measurement.
If ControlDesk detects no errors for the platform, it starts online calibration and displays the two measured signals in the Time Plotter.

The Time Plotter is automatically set to continuous visualization mode. This is the default setting for connecting variables of a real-time application.

The following Time Plotter elements give you more information on the currently active settings:
in the toolbar indicates that the Time Plotter is in continuous visualization mode.
The x-axis shows a continuing time axis, which indicates that no duration trigger is enabled.
The Raster column displays the measurement raster that is assigned to a signal.
In the Measurement Configuration pane, open Acquisition – Platform – 1 ms to see the trigger settings of the 1ms raster.

The start trigger (Platform Trigger 1) is disabled.
The stop trigger (Duration Trigger 1) is disabled.
If the Measurement Configuration pane is not visible, select the View ribbon and click Pane – Switch Panes – Measurement Configuration.
On the Time Plotter's toolbar, click
to display the DAQ info.

The DAQ info displays the currently active display mode of the Time Plotter.
Press F6 to stop the running measurement.
Press Ctrl+Shift+S to save the experiment.
You have placed two variables in a Time Plotter on the layout and started a continuous measurement with default measurement settings.
In the next step, you will switch from a continuous to a triggered measurement.