Step 1: How to Create a Recorder and Check its Signal List

Objective

In ControlDesk, recordings are managed via recorders. ControlDesk always creates one default recorder for each new experiment. You can create various further recorders with different signals to be recorded.

These signals are listed in recorder signal lists. A recorder signal list can be filled automatically with signals from the measurement signal list or manually, for example, by dragging variables from the Variables pane.

In this step you will create a new recorder and check the recorder signal lists of the default and the new recorder, before and after adding signals to the measurement signal list.


Video

Watch the video or follow the written instructions below.


Method: To create a recorder and check its signal list

  1. Open the DAQTutorialProject.

  2. If the DAQTutorialExperiment_Rec experiment is not already active, activate it via its context menu.

  3. In the Measurement Configuration pane, click Acquisition – Platform – 1ms and check the configuration settings for the 1 ms measurement raster.

    • Note that the signal list in the measurement configuration area (below the navigation tree) is empty because you have not selected a signal to be measured.

    • The navigation tree contains a default recorder element with the name Recorder 1.

  4. Click Recorders – Recorder 1 and check the configuration settings of the recorder.

    Note that the signal list of Recorder 1 is empty.

  5. Right-click Recorders and select Create New Recorder.

  6. Select Recorder 2 to check its configuration settings.

    • The signal list of Recorder 2 is also empty.

    • Note that Recorder 1 has a little in its symbol and Recorder 2 does not. The A stands for automatic and shows that Automatic signal configuration is enabled for Recorder 1. You can enable this property for each recorder, but for Recorder 1 it is enabled by default. Automatic signal configuration means that the signal list of a recorder is connected to the measurement signal list. Changes in the measurement signal list are automatically applied to the recorder signal list.

  7. Open the Variables pane, and select the Model Root node in the group view.

  8. From the variable list, select the following two variables and drag them onto Layout1 to place them in a Time Plotter:

    • Control_out

    • Throttle_act_pos

  9. From the variable list, select the following variable and drag it onto the 1ms raster node in the Measurement Configuration pane:

    • SigGenOut

    The chain symbols in the Variables pane show that 3 variables have been added to the measurement signal list. Two of them will be displayed in an instrument (red chain), one will be measured without visualization (yellow chain).

  10. In the Measurement Configuration pane, check the measurement signal list of the 1 ms raster and the signal lists of Recorder 1 and Recorder 2 as described in the following table.

    Selected Node

    Configuration

    Acquisition – Platform – 1ms

    The measurement signal list contains all the three selected signals.

    Recorders – Recorder 1

    The signal list of Recorder 1 contains all the three selected signals. They have been taken from the measurement signal list because Automatic signal configuration is enabled for the initial recorder by default (shown by an A in the recorder symbol).

    Recorders – Recorder 2

    The signal list of Recorder 2 contains no signals. They have not been taken from the measurement signal list because Automatic signal configuration is disabled for this recorder (no A in the recorder symbol).


Result

Your experiment now has two recorders.

  • The signal list of Recorder 1 has been filled together with the measurement signal list, because Automatic signal configuration was enabled for this recorder by default.

  • Recorder 2 contains no signal because signals must be added to this recorder manually as long as Automatic signal configuration is disabled in its properties.


What’s next

In the next step, you will add signals to Recorder 2 and configure the signal lists of both recorders.