Via the context menu of a measurement raster, you can easily switch between untriggered and triggered measurements.
Watch the video or follow the written instructions below.
Press F5 to start measuring.
In the Measurement Configuration, right-click the 1ms raster.
The
symbol next to the Measure Continuously (Disables Triggers) command indicates that all triggers are disabled and that measurement is performed continuously.

From the context menu, select Measure Triggered (Enables Triggers and Restarts Rasters).
The Time Plotter display is automatically set to triggered visualization mode:

The following Time Plotter elements give you more information on the trigger settings:
in the toolbar indicates that the Time Plotter is in triggered visualization mode.
The raster selection in the toolbar indicates that the trigger settings of the 1 ms measurement raster is used to trigger the Time Plotter display.
The x-axis now has a maximum value of 1.0 s, which indicates that a duration trigger of 1 second is enabled.
The DAQ info provides the following information:
The currently active display mode of the Time Plotter
The measurement raster that is used to trigger the display
The start time of the currently displayed measurement sample
Refer to the following illustration:

In the Measurement Configuration pane, open Acquisition – Platform – 1 ms.

The start trigger (Platform Trigger 1) and the stop trigger (Duration Trigger 1) are enabled.
Platform Trigger 1) is invalid, visualized by
.
Select Duration Trigger 1.

If Auto Repeat is disabled, enable it and click Start. The one‑second capture is started repeatedly.
If Auto Repeat or other sections are not visible, click the related
button on the left.
As long as Platform Trigger 1 has no trigger formula, it is invalid, visualized by
.
The duration trigger is set to a value of 1 second.
In the Time Plotter, the signal traces are renewed with each measurement raster start.
If not already active, click
to draw the curves on each new value.
Click
to draw the curves when a triggered capture is complete. This prevents the displayed signal from flickering.
Press F6 to stop the running measurement.
You have activated a triggered measurement for the 1 ms raster and configured the triggered visualization mode in the Time Plotter.
In the next step, you will learn to enable a start trigger.