How to Prepare Bus Configuration Tables for Working with the Tutorial

Objective

To work efficiently through the lessons of the Bus Manager tutorial, you have to ensure that the tables that are specific for bus configurations provide all the required columns. For this purpose, you have to reset the columns of the tables to their default state and add some additionally required columns to the tables.


Precondition

The BusManagerTutorial project is open.


Part 1: To prepare the Bus Configurations table

  1. Switch to the Buses view set.

    Tip

    If you use the Bus Manager (stand-alone), not all of the displayed view sets are available.

  2. Select the Bus Configurations table.

    Tip

    If the table is closed, you can open it via Windows on the Home ribbon.

  3. Right‑click in the Bus Configurations table and select Reset Columns on the context menu.

    This resets the columns of the table to the default state, i.e., this determines the available columns in the table and their order.

  4. Right‑click any column header and select Column Chooser on the context menu.

    The Column Chooser opens, displaying the columns that are available for the Bus Configurations table but not added yet to the table.

  5. In the Column Chooser, select the Related Clusters column header and drag it to the column header of the Bus Configurations table.

  6. Drag the Related TX ECUs and Related RX ECUs column headers from the Column Chooser to the Bus Configurations table.

  7. Close the Column Chooser.

  8. In the Bus Configurations table, sort the columns as follows:

    Tip

    The columns that are available in a table and their order is stored locally on the host PC and applies to all ConfigurationDesk applications. This applies even if you close the table, or ConfigurationDesk or the Bus Manager (stand‑alone).


Interim result

You reset the columns of the Bus Configurations table to the default state and added required columns. You can now prepare the Bus Access Requests table for working with the Bus Manager tutorial. Continue with the next part.


Part 2: To prepare the Bus Access Requests table

  1. Select the Bus Access Requests table.

  2. Right‑click in the Bus Access Requests table and select Reset Columns on the context menu.

    The columns of the Bus Access Requests table are reset to their default states. This is sufficient for working with the Bus Manager tutorial, i.e., you do not have to add any additional columns.


Interim result

You reset the columns of the Bus Access Requests table to the default state. You can now prepare the bus configuration feature tables for working with the Bus Manager tutorial. Continue with the next part.


Part 3: To prepare the bus configuration feature tables

  1. Select the Bus Simulation Features table.

  2. Select the Signal Features subview of the Bus Simulation Features table.

  3. Reset the columns of the Signal Features subview.

  4. Select the PDU Features subview and reset the columns of this subview.

  5. Select the Bus Inspection Features table and reset the columns of the Signal Features and PDU Features subviews.

  6. Select the Bus Manipulation Features table and reset the columns of the Signal Features and PDU Features subviews.

  7. Select the PDU Features subview of the Bus Manipulation Features.

  8. Adjust the width of the Bus Manipulation Features table until the Frame Length column is displayed. Depending on your screen size and resolution, you can achieve this by one or more of the following actions:

    • Right‑click any column header and select Best Fit All Columns on the context menu.

    • Enlarge the width of the table via the double‑headed arrow into which the cursor turns when you move it between the table border and another pane.

    • Reduce the width of individual columns via the double‑headed arrow into which the cursor turns when you move it between two column headers.

    Tip

    In general, you can navigate the tables via scrollbars. However, this is only possible when elements are available in the tables. Therefore, this is not possible yet.

  9. Right‑click any column header and select Column Chooser on the context menu.

    The Column Chooser displays the columns that are available for the PDU Features subview of the Bus Manipulation Features table but that are not added yet to the subview.

  10. Drag the Length - Frame Length and Padding Value - Frame Length columns to the right of the Frame Length column.

  11. Close the Column Chooser.


Interim result

You reset the columns of the bus configuration feature tables to the default state and added required columns. You can now prepare the Bus Configuration Ports table for working with the Bus Manager tutorial. Continue with the next part.


Part 4: To prepare the Bus Configuration Ports table

  1. Select the Bus Configuration Ports table.

  2. Reset the columns of the Bus Configuration Ports table.

  3. Adjust the width of the Bus Configuration Ports table until all columns are displayed.

  4. Right‑click any column header and select Column Chooser on the context menu.

  5. From the Bus Configuration Ports table, drag the Bus Configuration, Original Communication Matrix, Element Type, and Frame Identifiers columns to the Column Chooser.

  6. From the Column Chooser, drag the Related TX ECUs column header to the right of the Direction column in the Bus Configuration Ports table.

  7. Close the Column Chooser.


Result

You prepared the bus configuration tables for working with the Bus Manager tutorial. You can now start working with the Bus Manager tutorial: