To configure bus communication for inspection purposes, you have to add bus configuration features to elements that are assigned to the Inspection part of a bus configuration.
Select the Bus Inspection Features table.

The PDU Features subview is active, displaying all PDUs that are assigned to the Inspection part of bus configurations.
Select all displayed PDUs.
In the PDU Raw Data column, right-click one of the highlighted cells and select Fill with one of - Enabled on the context menu.

The PDU Raw Data feature is added to all the PDUs.
Click the Name column header to sort the PDUs alphabetically.
The sorting order is indicated by an arrow (
) in the column header.
Deselect the PDUs except for all CarLockControlIPdu and GearboxInfoIPdu PDUs.
For the selected PDUs, set PDU RX Status to Enabled.

The PDU RX Status feature is added to the selected PDUs.
Right-click any of the highlighted cells and select Show - Show in Bus Configurations Table on the context menu.
The Bus Configurations table is displayed, and the PDUs are highlighted in the table.
Expand the PDU nodes.
The lower-level elements of the PDUs are displayed, i.e., their PDU Raw Data and PDU RX Status feature nodes and their ISignals.
Expand a PDU Raw Data and a PDU RX Status feature node of a PDU.
The function ports of both features are displayed: One function port for the PDU Raw Data feature, five function ports for the PDU RX Status feature.

At run time, the function ports provide the raw data and status information of the inspected PDUs, e.g., the number of received PDU instances or the delta time between two consecutively received PDU instances.
For function ports of all bus inspection features, test automation support is enabled by default. This lets you access the function port values via experiment software and automation scripts without any additional configuration steps.
You added bus inspection features to PDUs. You can now add bus inspection features to ISignals. Continue with the next part.
In the Bus Inspection Features table, select the Signal Features subview.
All ISignals that are assigned to the Inspection part of bus configurations are displayed.
Click the Name column header to sort the ISignals alphabetically.
Select all Kl_15_ISignal and SpeedISignal ISignals.
For the selected ISignals, set ISignal Value to Enabled.

The ISignal Value feature is added to the selected ISignals.
The ISignal Value feature is also available as a bus simulation feature. In contrast to the simulation feature, you have to manually add the ISignal Value inspection feature to assigned ISignals.
You added bus configuration features to PDUs and ISignals that are assigned to the Inspection part of the bus configuration.
After you configured a reasonable set of bus communication, it is recommended to check the configured bus communication for conflicts. However, this step is skipped in this lesson.
With this step, you finished the lesson. For a summary of the lesson and for more information, refer to Result of Lesson 6.