Configuring Bus Communication for Real-Time Applications Without Behavior Models

Introduction

You can implement bus communication in a real-time application without using a behavior model if signal values do not have to change dynamically during run time. For example, you do not need a behavior model if you only want to inspect the response of an ECU under test to manipulated static signal values.

Note

This use scenario applies only to the Bus Manager in ConfigurationDesk, not to the Bus Manager (stand-alone).


Workflow

The following table shows detailed workflow steps and indicates the related topics and lessons of this tutorial that guide you through the individual steps.

Step

Work

Related Topic/Lesson

1

Create a new or open an existing ConfigurationDesk project and application.

How to Open the BusManagerTutorial Project

2

Add communication matrices and bus configurations to the ConfigurationDesk application.

Lesson 1: Adding Communication Matrices and Bus Configurations to the ConfigurationDesk Application

1

Add a communication matrix.

2

Add a bus configuration.

3

Assign communication matrix elements to bus configurations for simulation, inspection, and/or manipulation purposes.

Simulation

Lesson 2: Configuring Bus Communication for Simulation Purposes

1

Assign communication matrix elements to the Simulated ECUs part of a bus configuration.

2

Configure bus communication for simulation by using bus configuration features.

Inspection

Lesson 6: Configuring Bus Communication for Inspection Purposes

1

Assign communication matrix elements to the Inspection part of a bus configuration.

2

Configure bus communication for inspection by using bus configuration features.

Manipulation

Lesson 7: Configuring Bus Communication for Manipulation Purposes

1

Assign communication matrix elements to the Manipulation part of a bus configuration.

2

Configure bus communication for manipulation by using bus configuration features.

4

Create an application process that provides a default task.

Lesson 8: Working Without a Behavior Model

5

Specify access to real-time hardware and build a real-time application.

Lesson 5: Building a Real-Time Application

1

Add a hardware topology to the ConfigurationDesk application.

2

Specify the access to the bus for the bus configuration. To do this, assign the bus access requests of the bus configuration to bus accesses, i.e., to bus function blocks (CAN or LIN function blocks).

3

Assign hardware resources to the bus function blocks.

4

Configure the bus function blocks according to your requirements.

5

Check the Conflicts Viewer for conflicts and resolve them, if necessary.

6

Start the build process.


Redaction