To access bus configuration elements via experiment software or automation scripts, you have to do the following:
Assign communication matrix elements to a bus configuration.
Add bus configuration features that provide function ports to elements in the bus configuration.
Enable test automation support for function ports.
Switch to the Buses view set, if necessary.
In the Buses Browser, select Communication Matrices by Clusters.
Drag the LinDoorCluster node to the Simulated ECUs part of the Restbus_BusConfiguration in the Bus Configurations table.

In the Name column of the Bus Configurations table, change the name of the communication matrix node to BusManagerTutorial_ComMatrix.

It is recommended to use only names without date and version information, especially if you work with automation scripts later on.
Renaming the communication matrix node in the bus configuration applies only to this bus configuration. It does not apply to other bus configurations or the communication matrix file name.
Assign further communication matrix elements to the bus configuration:
From the CanBodyCluster, assign the BodyControlEcu to the Simulated ECUs part.
From the CanPowertrainCluster, assign the following elements of the GearboxEcu to the Simulated ECUs part:
PowerStatusIPdu
SpeedISignal of the GearboxInfoIPdu

You added communication matrix elements to the Simulated ECUs part of the Restbus_BusConfiguration. To the assigned elements, the ISignal Value and LIN Schedule Table feature are added automatically. You can now enable test automation support for the function ports of these features. Continue with the next part.
Select the Bus Configuration Ports table.

Select all displayed function ports, e.g., by pressing Ctrl+A.
Right-click a cell of the Test Automation Support column and select Fill with one of - Enabled on the context menu.

You enabled test automation support for all the available function ports. You can now enable LIN communication by default. Continue with the next part.
Select the LinDoorCommController Schedule Index function port.
In the Properties Browser, set the Initial value to 1.

This selects the first LIN schedule table of the LIN master communication controller and enables LIN communication by default.
By default, the Initial switch setting of function inports is set to Model signal. If function ports are not mapped to ports of a behavior model, the specified Initial value is used as the function port's default value. Therefore, it is not necessary to change the default value of the Initial switch setting if you work without a behavior model.
You enabled LIN communication by default. You can now check the configured bus communication for conflicts and resolve conflicts, if required. Continue with the next part.
In the Conflicts Viewer, click the expand arrow of the context set filter.

The context sets are displayed. In the illustration above, no context sets are selected.
The selection of context sets is stored locally on the host PC and applies to all ConfigurationDesk applications. The selection is preserved even when you close ConfigurationDesk or the Bus Manager (stand-alone). Therefore, the selected context sets in your ConfigurationDesk application might differ.
If you work with the Bus Manager (stand-alone), not all of the context sets that are displayed above are available.
The Shared Data Interface context set is available only as of Bus Manager 26.3.
Select the Bus Configurations context set and make sure that all other context sets are cleared.
Make sure that the Errors and Warnings filters are selected.

The Conflicts Viewer displays all conflicts of the Bus Configurations context set.

The Exceeding PDUs and/or update bits (bus configuration) conflict results from a frame for which the communication matrix specifies conflicting settings. The other conflicts result from the configuration state of the bus communication in the bus configuration.
If you work with the Bus Manager (stand-alone), the No bus access assigned conflict is not displayed. This is because the Bus Manager (stand-alone) displays only conflicts that are relevant for the fields of application in which the Bus Manager (stand-alone) can be used.
Completely expand the Exceeding PDUs and/or update bits (bus configuration) node.
For the DoorLeftStatusCanFrame, specify 2 as the value of the Length property.

By this, you change the frame length from 1 byte to 2 bytes, which matches the 2 bytes of the related PDU. This change applies to the bus configuration and the communication matrix in the ConfigurationDesk application, and resolves the conflict.
You will automatically resolve the No valid application process assigned conflict in step 3 of this lessen.
In the context of this lesson, you can ignore the No bus access assigned conflict.
In the Conflicts Viewer, click the context set filter.

All context sets are cleared and the Conflicts Viewer displays no conflicts.
You configured bus communication for simulation purposes and access via experiment software and automation scripts.
For optimum performance, note the following:
Do not enable model access for function ports if you work without a behavior model.
It is recommended to display conflicts only when and as long as required.
In the next step, you will create an application process that provides a default task.