To configure the run-time behavior for manipulating bus communication, you can specify feature-specific and common manipulation settings for each PDU and ISignal to which you added bus manipulation features.
In the Bus Manipulation Features table, select the PDU Features subview.
Click the Name column header to sort the PDUs alphabetically.
For the CarLockControlIPdu and GearboxInfoIPdu, set Countdown Start Value to 15.
The specified value applies to all bus manipulation features that are added to each of the PDUs.
For the CarLockControlIPdu, set Length - Frame Length to 1.

This value applies only to the Frame Length feature: When the feature is active at run time, the payload length of the frame that transmits the PDU is set to 1 byte by default.
Right-click the CarLockControlIPdu and select Show - Show in Bus Configurations Table on the context menu.
The Bus Configurations table is displayed and the PDU is highlighted in the table.
Expand the CarLockControlIPdu node to display its feature nodes and ISignals.
Expand the Suspend Frame Transmission feature node to display the function ports that are available for the feature.
The displayed function ports are common manipulation function ports. They are available for all bus manipulation features that can be added to PDUs.
Select the Suspend Frame Transmission feature node.
The Properties Browser displays the properties of the Suspend Frame Transmission feature node.
The values of the properties that are available for the Initial Feature Values category can be accessed via their related function ports at run time. The value of the Countdown start value property is derived from the value you specified in the Bus Manipulation Features table.

In the Properties Browser, set Enable to 1: Permanently enabled.
By default, the Suspend Frame Transmission feature is permanently enabled at run time, i.e., the frame is not transmitted. At run time, you can switch the enable state via the Enable function port.
You can specify the initial enable state of bus manipulation features that are available for PDUs only via the feature node or the Enable function port. You cannot specify the initial enable state via the Bus Manipulation Features table.
For function ports of all bus manipulation features, test automation support is enabled by default. This lets you access the function port values via experiment software and automation scripts without any additional configuration steps.
In the Bus Configurations table, expand the Frame Length feature node to display its function ports.
Select the Frame Length feature node.
The Properties Browser displays the properties of the Frame Length feature node.

In addition to the common Countdown start value and Enable properties, the Initial Feature Values category provides a Length property. The property value is the value you specified in the Bus Manipulation Features table. At run time, you can change the specified value via the Length function port that is available for the Frame Length feature.
Additionally, a Padding value property is available. If you extend the length of a frame, the added bytes are filled with the specified padding value at run time. You can also access this property via the Bus Manipulation Features table. However, you cannot change the specified padding value at run time. Therefore, the property is not part of the Initial Feature Values category and no function port is available.
In the Properties Browser, set the Countdown start value to 10.
The specified value applies only to the Frame Length feature. This lets you specify different countdown start values for the bus manipulation features that are added to a PDU.
You configured the run-time behavior for PDU manipulation. You can now configure the run-time behavior for ISignal manipulation. Continue with the next part.
In the Bus Manipulation Features table, select the Signal Features subview.
Click the Name column header to sort the ISignals alphabetically.
Select the SpeedISignal and set Feature Switch to 3: ISignal Offset Value (permanently).

When you add bus manipulation features to ISignals, a feature switch is available for each ISignal. The feature switch lets you specify the initially active bus manipulation feature and its enable state, i.e., permanently or temporarily enabled. You can change the specified initial setting at run time.
In the Bus Manipulation Features table, specify further settings as follows:
ISignal | Setting | Value |
|---|---|---|
SpeedISignal | Countdown Start Value | 25 |
Overwrite Value - ISignal Overwrite Value | 255 | |
Offset Value - ISignal Offset Value | 3 | |
DoorLeftLockedISignal | Feature Switch | 1: ISignal Overwrite Value (permanently) |
DoorRightLockedISignal | Countdown Start Value | 20 |
The specified overwrite value and offset value are feature-specific settings and apply only to the ISignal Overwrite Value and ISignal Offset Value feature, respectively. When the related feature is active at run time, the original ISignal value is manipulated by the specified value by default.
After you finish, the following settings are displayed in the Bus Manipulation Features table.

Right-click the SpeedISignal and select Show - Show in Bus Configurations Table on the context menu.
In the Bus Configurations table, expand the SpeedISignal node and its lower-level nodes.

The feature switch provides the common manipulation function ports. Therefore, these function ports are available only once for the ISignal and not for each of the added bus manipulation features. The bus manipulation features provide only feature-specific function ports.
The feature switch node and the feature nodes provide properties that let you specify common manipulation settings and feature-specific manipulation settings, respectively. These settings are identical to the settings that are available in the Bus Manipulation Features table. You can use the function ports to change the specified settings at run time.
You configured the run-time behavior for PDU and ISignal manipulation.
After you configured a reasonable set of bus communication, it is recommended to check the configured bus communication for conflicts. However, this step is skipped in this lesson.
With this step, you finished the lesson. For a summary of the lesson and for more information, refer to Result of Lesson 7.