When you start online calibration, you can simulate the LIN communication that you configured with the Bus Manager. You can use ControlDesk instruments to access the LIN communication.
On the Home ribbon, click
.
Online calibration starts and the LIN communication is active:
Bus Instrument (TX status type): In the Communication Controllers - LIN Schedule Table Access region, Actual Value displays the current value of the Schedule Index function port, which is 1. This indicates that the first schedule table of the LIN master communication controller is selected and the LIN communication on the LinDoorCluster is enabled.

Bus Instruments (RX type): In the PDUs - PDU RX Status Access regions, the values of the Counter, Time, and Delta Time function ports are running. This indicates that the DoorRightStatusIPdu and DoorLeftStatusIPdu are received by the BodyControlEcu.

In the LIN Schedule Table Access region of the Bus Instrument (TX status type), set the Source Switch to Substitute value.
The source of the Schedule Index function port is switched to the Substitute Value, which is 0. The displayed Actual Value indicates that this is the current function port value.
Because the value of the Schedule Index function port is set to 0, no schedule table is selected and the entire LIN communication on the LinDoorCluster is disabled. As a result, the values of the Counter, Time, and Delta Time function ports in both Bus Instrument (RX type) stop.
Set the Source Switch to Model signal to enable the LIN communication again.
In the Bus Instrument (TX status type), go to Communication Controllers -Communication Controller Enable Access - DoorLeftEcu.
Set the Substitute Value of the Enable function port to False.

The substitute value of the function port is set to False. However, the displayed Actual Value indicates that this is not the current function port value.
Set the Source Switch of the Enable function port to Substitute value.
The source of the function port value is switched from the model signal to the substitute value, i.e., the current function port value is False. This disables the communication controller of the DoorLeftEcu and the LIN communication of the ECU stops. Therefore, the DoorLeftStatusIPdu is not transmitted and it cannot be received by the BodyControlEcu. Nevertheless, the transmission of the DoorRightStatusIPdu is not affected.
Set the Substitute Value of the Enable function port to True.
The communication controller of the DoorLeftEcu is enabled. The ECU transmits the DoorLeftStatusIPdu, and the BodyControlEcu receives the PDU.
In the Bus Instrument (TX type), go to Signals - ISignal Value Access - DoorRightClosedISignal.
Set the Source Switch of the Value function port to Substitute value.
The substitute value of the ISignal is transmitted and received by the BodyControlEcu.

In the PDU Enable Access region of the Bus Instrument (TX type), set the Source Switch of the Enable function port to Substitute value.
In the PDU Enable Access region of the Bus Instrument (TX status type), the Source Switch of the Enable function port of DoorRightStatusIPdu (DoorRightEcu) changes accordingly because it is the same source switch.

Clear the Enable checkbox.
The transmission of the DoorRightStatusIPdu is disabled. In the PDU State region of the Bus Instrument (TX type), the color of the LED changes from green to red.

On the Home ribbon, click
.
Online calibration stops.
You simulated the LIN communication that you configured with the Bus Manager and accessed the communication via instruments.
In the next step, you will prepare a layout to simulate, manipulate, and inspect CAN communication.